{"title":"Liquid cooling","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eLiquid cooling removes heat where air simply runs out of capacity. Our range covers coolant distribution units, direct-to-chip kits, rear-door heat exchangers and complete hydro racks — from a single 26 kW unit to 154 kW cabinets.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eThe same hardware serves two markets: hydro-cooled ASIC farms and high-density GPU\/AI nodes. For AI operators it is often the most cost-effective route to liquid cooling, since the price per kilowatt of dissipation sits well below purpose-built datacenter systems. Every deployment is sized, supplied and supported by our engineers, with EU stock and warranty.\u003c\/p\u003e","products":[{"product_id":"28-slot-154kw-hydro-cooling-rack","title":"28-Slot 154kW Hydro Cooling Rack — Antminer S19\/S21\/S23 Hyd","description":"\u003c!-- IMAGE PLACEHOLDER 1 (main): front view of the assembled 28-slot cabinet, white background --\u003e\n\u003c!-- IMAGE PLACEHOLDER 2: rear view showing manifold and quick-connect ports --\u003e\n\u003c!-- IMAGE PLACEHOLDER 3: close-up of the coolant distribution manifold --\u003e\n\u003c!-- IMAGE PLACEHOLDER 4: cabinet installed in a data hall \/ farm (context shot) --\u003e\n\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eA 154 kW closed-loop hydro cooling cabinet built for high-density deployments. It houses up to 28 hydro-cooled units in a single frame, with an integrated coolant loop, distribution manifold and quick-connect fittings on every slot — so a full row can be brought online in hours rather than days.\u003c\/p\u003e\n\u003cp\u003eThe same platform serves two very different workloads. For miners it removes the heat of 28 hydro ASICs without the noise and airflow problems of fan-cooled halls. For AI operators it is one of the most cost-effective ways to cool dense GPU nodes: the thermal engineering is identical, but the price per kilowatt of dissipation is far below purpose-built datacenter CDUs.\u003c\/p\u003e\n\n\u003ch3\u003eWhy teams choose this cabinet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e154 kW in one frame\u003c\/strong\u003e — 28 slots, each with its own supply and return connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet by design\u003c\/strong\u003e — heat leaves through liquid, not through walls of fans, so ambient noise drops dramatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast deployment\u003c\/strong\u003e — pre-plumbed manifold and quick-connects; no custom pipework per unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable under sustained load\u003c\/strong\u003e — liquid holds temperatures flat, which protects boost clocks and hardware lifetime in 24\/7 operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-purpose\u003c\/strong\u003e — equally suited to hydro ASICs and to liquid-cooled GPU\/AI nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHydro mining farms running Antminer S19 \/ S21 \/ S23 Hyd series\u003c\/li\u003e\n\u003cli\u003eHigh-density AI and HPC nodes where air cooling has hit its limit\u003c\/li\u003e\n\u003cli\u003eHeat-reuse projects — the warm return loop can feed building or process heating\u003c\/li\u003e\n\u003cli\u003eSites where noise or airflow constraints rule out conventional cooling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat you get from Kentino\u003c\/h3\u003e\n\u003cp\u003eWe supply, configure and support the cabinet as part of a complete deployment: layout planning, power and coolant sizing, EU-based logistics and warranty. If you are pairing it with GPU servers rather than ASICs, our engineers will confirm compatibility and specify the loop before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLead time and freight are quoted per project — this item ships as heavy freight. Contact us for a delivery estimate to your site.\u003c\/em\u003e\u003c\/p\u003e","brand":"Kentino","offers":[{"title":"Default Title","offer_id":53643202298184,"sku":"KEN-HC-154-28","price":2989.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/5479\/3800\/files\/28-slot-154kw-hydro-cooling-rack.jpg?v=1785831968"},{"product_id":"24kw-hydro-cooling-rack-antrack-v1","title":"24kW 4-Slot Hydro Cooling Rack — Bitmain ANTRACK V1","description":"\u003c!-- IMAGE PLACEHOLDER 1 (main): front view of the ANTRACK V1 frame, white background --\u003e\n\u003c!-- IMAGE PLACEHOLDER 2: manifold connection detail --\u003e\n\u003c!-- IMAGE PLACEHOLDER 3: frame with four units mounted --\u003e\n\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eBitmain's original four-slot hydro frame, rated at 24 kW. It is the rack half of the equation only — mounting, manifold and connections for four hydro units, designed to sit on a coolant loop you supply.\u003c\/p\u003e\n\u003cp\u003eAt this price it is the cheapest legitimate way to hold four hydro units on a proper manifold, and it is frequently bought as a bench frame for testing loops, fittings and coolant before a larger deployment. Useful for AI teams for exactly the same reason.\u003c\/p\u003e\n\n\u003ch3\u003eWhy teams choose it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 kW across 4 slots\u003c\/strong\u003e — Bitmain's original hydro rack format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame and manifold\u003c\/strong\u003e — connects to a coolant loop you already run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLowest entry price\u003c\/strong\u003e — the cheapest proper four-slot hydro mount.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePopular as a test bench\u003c\/strong\u003e — for validating loops and fittings before scale.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmall four-unit hydro deployments\u003c\/li\u003e\n\u003cli\u003eBench testing coolant loops and fittings\u003c\/li\u003e\n\u003cli\u003eSpare-capacity frames on an existing site\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat you get from Kentino\u003c\/h3\u003e\n\u003cp\u003eKentino supplies, configures and supports this hardware as part of a complete deployment: layout planning, coolant and power sizing, EU-based logistics and warranty. If you are pairing it with GPU servers rather than ASICs, our engineers will confirm compatibility and specify the loop before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLead time and freight are quoted per project. Contact us for a delivery estimate to your site.\u003c\/em\u003e\u003c\/p\u003e","brand":"Kentino","offers":[{"title":"Default Title","offer_id":53643807064392,"sku":"KEN-HC-24-V1","price":810.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/5479\/3800\/files\/24kw-hydro-cooling-rack-antrack-v1.jpg?v=1785838798"},{"product_id":"15kw-hydro-cooling-radiator","title":"15kW Hydro Cooling Radiator — Antminer \u0026 Whatsminer Hyd","description":"\u003c!-- IMAGE PLACEHOLDER 1 (main): front view of the 15kW radiator, white background --\u003e\n\u003c!-- IMAGE PLACEHOLDER 2: fitting and port detail --\u003e\n\u003c!-- IMAGE PLACEHOLDER 3: radiator installed outdoors on a loop --\u003e\n\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eA 15 kW radiator module with fittings compatible with both Antminer and Whatsminer hydro hardware — useful on mixed sites where standardising on one rejection component simplifies spares.\u003c\/p\u003e\n\u003cp\u003eThree extra kilowatts over the 12 kW modules sounds marginal until a hot week arrives and the loop has nowhere to put the heat. Buying rejection capacity slightly oversized is one of the cheapest forms of insurance in a liquid-cooled installation, whether the load is ASICs or GPUs.\u003c\/p\u003e\n\n\u003ch3\u003eWhy teams choose it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 kW rejection\u003c\/strong\u003e — extra margin over the 12 kW modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-compatible fittings\u003c\/strong\u003e — works with Antminer and Whatsminer hydro.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplifies spares\u003c\/strong\u003e — one rejection part across a mixed site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-contained\u003c\/strong\u003e — integrated fans, no chiller plant required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMixed Antminer and Whatsminer hydro sites\u003c\/li\u003e\n\u003cli\u003eLoops needing extra summer margin\u003c\/li\u003e\n\u003cli\u003eSmall liquid-cooled AI deployments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat you get from Kentino\u003c\/h3\u003e\n\u003cp\u003eKentino supplies, configures and supports this hardware as part of a complete deployment: layout planning, coolant and power sizing, EU-based logistics and warranty. If you are pairing it with GPU servers rather than ASICs, our engineers will confirm compatibility and specify the loop before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLead time and freight are quoted per project. Contact us for a delivery estimate to your site.\u003c\/em\u003e\u003c\/p\u003e","brand":"Kentino","offers":[{"title":"Default Title","offer_id":53643807293768,"sku":"KEN-RAD-15","price":354.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/5479\/3800\/files\/15kw-hydro-cooling-radiator.jpg?v=1785838470"},{"product_id":"1-2mw-210-slot-integrated-hydro-cooling-container-40hq","title":"1.2MW 210-Slot Integrated Hydro Cooling Container — 40HQ","description":"\u003c!-- IMAGE PLACEHOLDER 1 (main): exterior of the 40HQ container, white background --\u003e\n\u003c!-- IMAGE PLACEHOLDER 2: interior aisle view showing racks both sides --\u003e\n\u003c!-- IMAGE PLACEHOLDER 3: heat rejection plant detail --\u003e\n\u003c!-- IMAGE PLACEHOLDER 4: container on site, installed --\u003e\n\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe same 1.2 MW capacity and 210 slots as the 20-foot unit, built into a 40-foot high-cube shell. The extra length buys service aisles, larger heat rejection plant and room to work inside the container rather than only at its face.\u003c\/p\u003e\n\u003cp\u003eServiceability is what separates a container that runs for five years from one that becomes unmaintainable after eighteen months. If the site has space for a 40-foot unit, the additional cost is small relative to what it saves in maintenance access — a point that applies whether the racks hold ASICs or GPU nodes.\u003c\/p\u003e\n\n\u003ch3\u003eWhy teams choose it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.2 MW, 210 slots\u003c\/strong\u003e — same capacity as the 20HQ, more room to work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal service aisles\u003c\/strong\u003e — maintenance from inside, not only at the face.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarger rejection plant\u003c\/strong\u003e — more thermal margin in hot climates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully integrated\u003c\/strong\u003e — cooling, power distribution and monitoring included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLong-life hydro mining installations\u003c\/li\u003e\n\u003cli\u003eAI clusters where maintenance access matters\u003c\/li\u003e\n\u003cli\u003eHot-climate sites needing extra rejection margin\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat you get from Kentino\u003c\/h3\u003e\n\u003cp\u003eKentino supplies, configures and supports this hardware as part of a complete deployment: layout planning, coolant and power sizing, EU-based logistics and warranty. If you are pairing it with GPU servers rather than ASICs, our engineers will confirm compatibility and specify the loop before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLead time and freight are quoted per project. Contact us for a delivery estimate to your site.\u003c\/em\u003e\u003c\/p\u003e","brand":"Kentino","offers":[{"title":"Default Title","offer_id":53643807457608,"sku":"KEN-CT-12-210-40","price":64768.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/5479\/3800\/files\/1-2mw-210-slot-integrated-hydro-cooling-container-40hq.jpg?v=1785838162"},{"product_id":"1-4mw-240-slot-hydro-cooling-container-20hq","title":"1.4MW 240-Slot Hydro Cooling Container — 20HQ Turnkey","description":"\u003c!-- IMAGE PLACEHOLDER 1 (main): exterior of the container, white background --\u003e\n\u003c!-- IMAGE PLACEHOLDER 2: interior showing 240-slot density --\u003e\n\u003c!-- IMAGE PLACEHOLDER 3: external heat rejection arrangement --\u003e\n\u003c!-- IMAGE PLACEHOLDER 4: installed container with connections visible --\u003e\n\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eTwo hundred and forty slots and 1.4 MW inside a 20-foot high-cube shell — the highest power density per square metre of any container we supply, achieved by tightening slot pitch and moving heat rejection outside the box.\u003c\/p\u003e\n\u003cp\u003eDensity per square metre becomes the deciding number when land or floor area is expensive, or when a site's footprint is fixed by permitting rather than by power. In those situations this container delivers more compute per permitted square metre than any alternative, regardless of whether the load is mining or AI inference.\u003c\/p\u003e\n\n\u003ch3\u003eWhy teams choose it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.4 MW in a 20-foot shell\u003c\/strong\u003e — the highest density per square metre we supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e240 slots\u003c\/strong\u003e — tight pitch with external heat rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFootprint-efficient\u003c\/strong\u003e — for sites limited by area rather than power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurnkey\u003c\/strong\u003e — cooling, distribution and monitoring integrated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSites where land or floor area is the binding constraint\u003c\/li\u003e\n\u003cli\u003eMaximum-density hydro mining deployments\u003c\/li\u003e\n\u003cli\u003eHigh-density AI inference capacity on a fixed footprint\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat you get from Kentino\u003c\/h3\u003e\n\u003cp\u003eKentino supplies, configures and supports this hardware as part of a complete deployment: layout planning, coolant and power sizing, EU-based logistics and warranty. If you are pairing it with GPU servers rather than ASICs, our engineers will confirm compatibility and specify the loop before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLead time and freight are quoted per project. Contact us for a delivery estimate to your site.\u003c\/em\u003e\u003c\/p\u003e","brand":"Kentino","offers":[{"title":"Default Title","offer_id":53643807490376,"sku":"KEN-CT-14-240-20","price":64768.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/5479\/3800\/files\/1-4mw-240-slot-hydro-cooling-container-20hq.jpg?v=1785837727"},{"product_id":"1-7mw-308-slot-hydro-cooling-container-40hq","title":"1.7MW 308-Slot Hydro Cooling Container — 40HQ Turnkey","description":"\u003c!-- IMAGE PLACEHOLDER 1 (main): exterior of the 40HQ container, white background --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- IMAGE PLACEHOLDER 2: interior aisle showing 308 slots --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- IMAGE PLACEHOLDER 3: power distribution and monitoring detail --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- IMAGE PLACEHOLDER 4: multiple containers installed on site --\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe largest single container in the range: 308 slots and 1.7 MW in a 40-foot high-cube shell, with cooling, power distribution and monitoring built in and commissioned before delivery.\u003c\/p\u003e\n\u003cp\u003eAt 1.7 MW a single container carries what used to require a small building. Deployed in multiples it is how megawatt-scale sites now get built — each unit is an identical, tested block of capacity, which makes both the schedule and the cost predictable in a way that construction never is. The model works the same for a mining farm and for an AI training cluster.\u003c\/p\u003e\n\u003ch3\u003eWhy teams choose it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.7 MW, 308 slots\u003c\/strong\u003e — the largest single container we supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeployed in multiples\u003c\/strong\u003e — megawatt-scale sites built from identical blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePredictable cost and schedule\u003c\/strong\u003e — tested capacity instead of construction risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully integrated\u003c\/strong\u003e — cooling, power and monitoring commissioned before delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMegawatt-scale hydro mining farms\u003c\/li\u003e\n\u003cli\u003eLarge AI training clusters built in repeatable blocks\u003c\/li\u003e\n\u003cli\u003eOperators scaling capacity against a fixed timeline\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat you get from Kentino\u003c\/h3\u003e\n\u003cp\u003eKentino supplies, configures and supports this hardware as part of a complete deployment: layout planning, coolant and power sizing, EU-based logistics and warranty. If you are pairing it with GPU servers rather than ASICs, our engineers will confirm compatibility and specify the loop before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLead time and freight are quoted per project. Contact us for a delivery estimate to your site.\u003c\/em\u003e\u003c\/p\u003e","brand":"Kentino","offers":[{"title":"Default Title","offer_id":53643807916360,"sku":"KEN-CT-17-308-40","price":93003.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/5479\/3800\/files\/1-7mw-308-slot-hydro-cooling-container-40hq.jpg?v=1785835804"},{"product_id":"500kw-gas-powered-hydro-mining-container-96-slot","title":"500kW Gas-Powered Hydro Cooling Container — 96 Slots","description":"\u003c!-- IMAGE PLACEHOLDER 1 (main): exterior of the container, white background --\u003e\n\u003c!-- IMAGE PLACEHOLDER 2: interior showing the 96 liquid-cooled slots --\u003e\n\u003c!-- IMAGE PLACEHOLDER 3: generator sets and switchgear --\u003e\n\u003c!-- IMAGE PLACEHOLDER 4: dry coolers mounted externally --\u003e\n\u003c!-- IMAGE PLACEHOLDER 5: container installed on a remote site --\u003e\n\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eA single container that both generates its own power and cools the hardware it feeds: two 250 kW natural gas generator sets, 96 liquid-cooled slots, two high-efficiency micro-channel dry coolers rated for the full 500 kW, plus networking and ventilation.\u003c\/p\u003e\n\u003cp\u003eThis is the format for sites that have gas and nothing else — no grid, no building, no cooling infrastructure. Everything the deployment needs arrives on one truck and is commissioned as one system, which also means one supplier is answerable for the whole thing rather than three arguing about whose interface failed. The liquid-cooled slots take hydro ASICs today and liquid-cooled GPU nodes without mechanical change.\u003c\/p\u003e\n\n\u003ch3\u003eWhy teams choose it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower and cooling in one unit\u003c\/strong\u003e — 500 kW generated and rejected inside the same container.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e96 liquid-cooled slots\u003c\/strong\u003e — hydro ASICs or liquid-cooled GPU nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicro-channel dry coolers\u003c\/strong\u003e — two units rated for the full 500 kW load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuinely off-grid\u003c\/strong\u003e — needs a gas supply and nothing else.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote sites with gas but no grid connection\u003c\/li\u003e\n\u003cli\u003eFlare-gas monetisation with liquid-cooled hardware\u003c\/li\u003e\n\u003cli\u003eFast off-grid AI or mining capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat you get from Kentino\u003c\/h3\u003e\n\u003cp\u003eKentino supplies, configures and supports this system as part of a complete deployment: site and load assessment, gas supply and emissions requirements, electrical design, EU-based logistics and warranty. On-site generation carries permitting and emissions obligations that vary by country — our engineers will walk through what applies to your location before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLead time and freight are quoted per project. Contact us for a full bill of materials and a delivery estimate to your site.\u003c\/em\u003e\u003c\/p\u003e","brand":"Kentino","offers":[{"title":"Default Title","offer_id":53650409554248,"sku":"KEN-PW-CT-50H","price":187220.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/5479\/3800\/files\/500kw-gas-powered-hydro-mining-container-96-slot.png?v=1785934168"}],"url":"https:\/\/kentino.com\/he\/collections\/liquid-cooling.oembed","provider":"Kentino","version":"1.0","type":"link"}