NVIDIA RTX PRO 6000 Blackwell Server Edition 96 GB GDDR7 ECC
NVIDIA RTX PRO 6000 Blackwell Server Edition 96 GB GDDR7 ECC
No se pudo cargar la disponibilidad de retiro
NVIDIA RTX PRO 6000 Blackwell Server Edition — 96 GB
The datacenter variant: 96 GB of unified ECC GDDR7, passively cooled for front-to-back rack airflow, with a configurable 400–600 W power envelope. Built to run continuously in a server chassis rather than on a desk.
Built for 24/7 rack operation
The Server Edition carries the same Blackwell die and the same 96 GB ECC memory pool as the workstation cards, but is engineered for a different environment. It has no fan and no display outputs: cooling comes from the chassis, in a front-to-back path, which is what makes dense multi-GPU rack builds possible in the first place. The power envelope is configurable between 400 W and 600 W, so density and thermal budget can be traded against per-card throughput. This is the card behind Kentino's multi-GPU Kentino AI rack servers.
Technical data
| GPU | NVIDIA GB202 — Blackwell |
| Memory | 96 GB GDDR7 ECC, 512-bit |
| Memory bandwidth | ~1.8 TB/s |
| CUDA cores | 24,064 |
| Tensor cores | 752 (5th gen) · ~2,000 TOPS INT8 |
| RT cores | 188 (4th gen) |
| Interface | PCIe 5.0 ×16 |
| Board power | 400–600 W configurable |
| Cooling | Passive — requires chassis front-to-back airflow |
| Display outputs | None |
| Form factor | Dual-slot, full-height |
| Warranty | 3-year manufacturer warranty |
Where it fits
- Dense multi-GPU rack servers — 2, 4, 6 or 8 cards in a single chassis.
- Continuous 24/7 inference serving in a datacenter or server room.
- Shared or multi-tenant AI infrastructure where ECC and stability are requirements.
- Deployments where per-card power must be capped to fit a rack thermal budget.
- Large-model serving across several cards with 96 GB of unified VRAM each.
FAQ
Can I use this in a desktop PC?
No. It has no fan and relies entirely on chassis airflow designed for passive GPUs. In a normal tower case it will throttle and then overheat. Use the Workstation or Max-Q edition for tower and desk builds.
How does it compare with the workstation cards?
Identical GPU and identical 96 GB of ECC memory. The differences are physical: passive cooling, no display outputs, and a configurable 400–600 W envelope for rack density. Choose it only if you have a server chassis to put it in.
Why cap it at 400 W?
In a dense build, total rack power and cooling — not the individual card — is usually the limit. Capping each card lets you fit more GPUs into the same thermal budget, which typically yields more total throughput than fewer cards running flat out.
Do you supply complete servers with these?
Yes. The Kentino AI rack line is built around this card in 1, 2, 4, 6 and 8-GPU configurations, assembled, benchmarked and commissioned before delivery.